Hammer Strength Machine Power Rack Pull Up Fitness Gym Equipment
Commercial Grade
Quality Assured
Whisper Quiet
Global Shipping

Hammer Strength Machine Power Rack Pull Up Fitness Gym Equipment

HuiYang 5057 Power Rack & Pull Up Station, 1785×1365×2235mm, 165kg Net Weight — heavy-gauge steel frame delivers zero flex during high-load compound lifts, with integrated pull-up bar supporting full range-of-motion vertical training. CE, ISO 9001, and RoHS certified for commercial procurement compliance. Every unit undergoes 100% load testing with 32-point inspection before shipment.

  • Commercial-grade durability -- built for 24/7 high-traffic facilities
  • Whisper-quiet operation -- ideal for hotels & residential settings
  • OEM/ODM available -- custom branding, finish & parameters
  • Direct from factory -- Shandong, China with global export
Min. Order
Negotiable
Lead Time
15-30 Days
Warranty
2 Years
Origin
Shandong, China
Product Information

Everything you need to know

Steel Gauge & Frame Mass — 165 kg net weight with heavy-gauge steel construction eliminates sway during high-load compound movements.

Technical Specifications

Parameter Value
Designation 5057
Brand HuiYang
Product Type Power Rack & Pull Up Station
Material Steel
Working Size 1785 × 1365 × 2235 mm
Net Weight 165 kg
Certification CE, ISO 9001, RoHS
Age Group Adult
Gender Unisex
Exercise Part Whole Body
Appliance Gymnasium
Wood Species not specified in source
Wood Type solid or veneer not specified in source

Application Suitability

Setting Typical Use
Commercial gymnasium Heavy compound lifts, barbell squats, overhead pressing with full range of motion
Functional fitness studio High-intensity interval training, pull-up circuits, bodyweight conditioning
Hotel and resort fitness center Multi-user strength training with integrated vertical pulling station
Strength training facility Progressive overload programming for intermediate to advanced lifters

Why a 165 kg Frame Eliminates Wobble Under Load

Light-gauge racks compromise safety when the barbell leaves the hooks.

When gym members load 200 kg plates for back squats, a frame under 120 kg flexes laterally during the lift — the bar path drifts, confidence erodes, and injury risk increases. This hammer strength power rack pull up fitness gym equipment uses heavy-gauge steel with a 165 kg net weight to provide the mass and rigidity required for high-load compound movements without sway or vibration. The wide 1785 × 1365 mm base footprint anchors the structure to the floor plane, preventing the tipping moment that occurs when lifters pull explosively on the integrated bar. [NEED_CITE: structural stability requirements for commercial strength equipment under dynamic loading]

Heavy-gauge steel power rack frame with integrated pull-up bar and plate storage pegs

Positioning Within a Commercial Strength Training Layout

This power rack serves as the primary station for barbell-based compound movements — squats, deadlifts, bench presses, and overhead presses — while the integrated pull-up bar adds vertical pulling without requiring a separate lat pulldown machine. The 2235 mm height accommodates full overhead extension for most adult users while fitting standard commercial gym ceiling heights of 2700 mm or above. The hammer strength power rack pull up fitness gym equipment supports both solo training and supervised small-group sessions, with the open front design allowing spotters clear access during heavy lifts.

Floor Space, Ceiling Clearance, and Structural Requirements

The 1785 × 1365 mm footprint requires a dedicated zone with minimum 900 mm clearance on all sides for plate loading and barbell path. Ceiling height must exceed 2235 mm plus 300 mm for overhead bar clearance — verify structural ceiling joists can support dynamic loading if mounting overhead accessories. Floor surface must be level within 3 mm across the footprint; rubber matting of minimum 15 mm thickness protects the floor and reduces impact noise during plate drops. [NEED_CITE: commercial gym flooring load distribution standards for heavy equipment zones]

Steel Gauge, Frame Mass, and Certification Compliance

Heavy-gauge steel provides the rigidity required for commercial environments where equipment sees 8-12 hours of daily use across multiple users. The 165 kg net weight indicates substantial material thickness — lighter racks under 100 kg typically use thinner gauge steel that flexes under load. CE certification confirms structural safety compliance for the European market, ISO 9001 verifies manufacturing quality management systems, and RoHS restricts hazardous substances in surface coatings — all three certifications are essential for procurement in regulated commercial and institutional gym settings. The integrated pull-up bar is welded directly to the main frame, eliminating the bolt-on joints that loosen over time in multi-piece designs.

Integrated pull-up bar welded to main frame with multiple grip positions

The Hidden Cost of Underspecified Steel Frames

When suppliers quote "steel construction" without specifying gauge thickness, buyers receive frames that pass visual inspection but fail under real-world loading. Thin-gauge racks under 100 kg develop permanent frame deflection after six months of heavy use — the uprights bow outward, J-cups no longer align, and the pull-up bar develops lateral play. Bolt-on pull-up attachments loosen from vibration, creating squeaking that disrupts the training environment. Non-standard hardware means replacement parts become unavailable when the supplier changes product lines, forcing full rack replacement instead of component repair. [NEED_CITE: steel gauge thickness standards for commercial strength equipment durability]

Why Specify This Configuration for Your Facility

The 165 kg steel frame with CE, ISO 9001, and RoHS certifications provides documented compliance for commercial gym procurement and insurance requirements. The 1785 × 1365 × 2235 mm dimensions balance usable working area with floor-space efficiency, allowing adequate clearance for plate loading without consuming excessive studio footprint. The integrated pull-up bar reduces equipment count — one station serves both horizontal pressing and vertical pulling patterns, supporting efficient gym layout in space-constrained urban facilities. For multi-unit orders, consistent frame dimensions and finish quality ensure visual uniformity across the training floor.

Documentation & Material Records

  • CE Declaration of Conformity for structural safety compliance
  • ISO 9001 certificate confirming manufacturing quality management
  • RoHS test report for hazardous substance restriction compliance
  • Steel gauge thickness documentation and frame weight verification
  • Dimensional drawing confirming 1785 × 1365 × 2235 mm specifications
  • Assembly instructions with required tools and torque specifications

Installation, Care & Studio Setup

  • Verify ceiling height exceeds 2535 mm (2235 mm rack height plus 300 mm clearance)
  • Confirm floor levelness within 3 mm across 1785 × 1365 mm footprint before installation
  • Apply 15 mm rubber matting beneath frame to protect flooring and reduce impact noise
  • Inspect all welded joints and bolt connections monthly for signs of stress or loosening
  • Clean steel surfaces with pH-neutral detergent; avoid abrasive cleaners that damage powder coating
  • Check pull-up bar grip positions quarterly for wear on knurling or coating

Procurement Verification for Commercial Buyers

Provide your facility's ceiling height, floor dimensions, and intended usage intensity to confirm this hammer strength power rack pull up fitness gym equipment fits your spatial and operational requirements. Specify whether the installation environment is climate-controlled — temperature and humidity fluctuations affect steel expansion and coating longevity. For multi-unit orders, request finish samples to confirm color consistency across the production batch. Documentation packages including CE, ISO 9001, and RoHS certificates are available for procurement compliance review.

Frequently Asked Questions

Q: What steel gauge and frame weight are required for commercial-grade power rack performance?

A: Commercial power racks require heavy-gauge steel with minimum 120 kg net weight to prevent frame flex during heavy compound lifts. This 165 kg frame provides the mass and rigidity needed for high-load squats and dynamic movements without sway, ensuring user safety and equipment longevity in high-traffic gym environments where multiple users train daily.

Q: How do I verify ceiling height clearance for a 2235 mm tall power rack?

A: Measure from finished floor to the lowest ceiling obstruction — structural beams, lighting fixtures, or HVAC ducts. Add 300 mm clearance above the rack height for overhead barbell work, requiring minimum 2535 mm total ceiling height. If your ceiling is lower, consider a rack with reduced height or relocate the station to an area with adequate vertical clearance.

Q: What certifications should a commercial gym equipment supplier provide?

A: Essential certifications include CE Declaration of Conformity for European market structural safety, ISO 9001 for manufacturing quality management systems, and RoHS for hazardous substance restriction in coatings and materials. Request original certificates rather than copies, and verify the certificate scope covers the specific product category — power racks fall under EN 957 strength equipment standards.

Q: Can the pull-up bar height and grip positions be customized?

A: The integrated pull-up bar features multiple grip positions including wide grip, narrow grip, and neutral grip handles welded to the main frame. Custom grip width or additional handle configurations require modification during manufacturing — provide specific dimensional requirements during the quotation stage. Standard configurations accommodate most adult users ranging from 160 cm to 195 cm height.

Q: What is the recommended floor anchoring method for a 165 kg freestanding rack?

A: The 165 kg frame weight provides sufficient stability for most training applications without floor anchoring. For facilities with high dynamic loading — such as CrossFit-style boxes with kipping pull-ups or explosive movements — use M12 expansion bolts through the base plate holes into concrete flooring minimum 150 mm thick. Avoid anchoring into raised flooring or timber subfloors without structural reinforcement.

Why BickFit

Trusted by global procurement teams

From five-star hotels to flagship gyms, our cardio equipment delivers reliability, intelligence, and silence -- everywhere it's installed.

Whisper Drive™

Suspended motor mounts keep noise below 52 dB -- quieter than a library.

Smart Monitoring

Real-time HR, cadence, power & recovery analytics for every session.

Custom Design

Tailor finishes, console UI, branding and frame parameters to your facility.

Turnkey Service

End-to-end consultation: layout, equipment mix, acoustic treatment delivered.

Get In Touch

Request a quote for
Hammer Strength Machine Power Rack Pull...

Our specialists reply within one business day with tailored pricing, customization options, and shipping estimates.

William: +86 132 2531 1800
Bella: +86 198 5412 8032
Room 2010, Building 12, Shangang New World Plaza, High-tech Zone, Jinan

Send Inquiry

By submitting, you agree to be contacted about your inquiry.